Temporary hair loss using the long-pulsed alexandrite laser at 20 milliseconds


European Journal of Dermatology. Volume 10, Number 2, 103-6, March 2000, Thérapeutique


Summary  

Author(s) : C. Raulin, B. Greve, Center for Dermatologic Laser Therapy; Laserklinik Karlsruhe, Kaiserstrasse 104, D-76133 Karlsruhe, Germany. info@laserklinik.de www.raulin.de.

Summary : Facial hypertrichosis presents an enormous psychological burden for women. Temporary hair removal (waxing, plucking, etc.) and electrolysis are prolonged and unsatisfactory methods of treatment. For a few years several laser systems with varying wavelengths, pulse durations and energy fluences have been used successfully in laser epilation. In the retrospective study on hand, we report on results of 30 female patients with hypertrichosis in the facial area treated with the long pulse alexandrite laser at 20 msec (Cynosure PhotoGenica LPIR/Apogee; 755 nm; 20 msec; up to 30 J/cm2; 10 or 12.5 mm beam diameter) over an 18 month treatment period. After an average of 8 treatments, an average clearance rate of 75% could be achieved. Fair hair (white/blond/red) only showed a clearance rate of 10%. Hypo- and hyperpigmentation did not appear. The most frequent adverse effects were the occasional appearance of scattered crusting (17%), which healed without consequences, and folliculitis (13%). The average post-treatment observation time lasted 3.25 months. The long-pulsed alexandrite laser at a pulse duration of 20 msec is an effective and safe method of treatment of hypertrichosis in the facial region of women. Black hair responds considerably better to the laser treatment than fair hair. A longer post-treatment observation time is necessary, though, in order to provide evidence for the permanence of the success of the method.

Keywords : long pulse alexandrite laser, epilation, ruby laser, Epilight®, Photoderm®, hair removal

Pictures

ARTICLE

Hair removal by laser or laser-similar systems has become a major research subject and an economic force in the field of cutaneous laser medicine. Laser-assisted hair removal is attractive because it offers a rapid, relatively painless method for hair removal with minimal risks of scarring or other side effects. The market is overstocked with new lasers, but scientific studies on this subject are rare and the mechanism of action still remains to be proved since it is based on pure theory.

Research currently concentrates on the Q-switched neodymium:yttrium-aluminium-garnet (Nd:YAG), the long-pulsed ruby laser as well as the Epilight®/Photoderm®, an intense pulsed light source. The long-pulsed alexandrite laser and diode laser can be included as new variants. For many years, the removal of tattoos has been a well-known area of application for the alexandrite laser (though in the Q-switched mode) [1].

The long-pulsed alexandrite laser is currently available with pulse durations of 2, 5, 10, 20 and 40 msec and utilizes the principle of "selective photothermolysis" and "thermokinetic selectivity" [2, 3]. Long and high energetic pulses lead to thermal destruction of large pigmented cutaneous targets such as the follicle. Endogenous melanin-containing cells within the follicle and the hair shaft absorb the 755 nm light and are damaged, resulting in a delay of hair growth. To decrease the risk of epidermal injury resulting from absorption of the alexandrite laser light in superficial melanin-containing epidermal cells, the application of a cooling gel is necessary. The assumption that longer pulse durations increase efficacy and decrease the rate of side effects could nevertheless not be confirmed in scientific studies as yet [4, 5].

The objective was to investigate the efficacy and safety of the long-pulsed alexandrite laser with a pulse duration of 20 msec in the treatment of facial hypertrichosis on 30 female patients in a retrospective study.

Materials and methods

Data from a total of 30 female patients, randomly selected, with facial hypertrichosis (from 09/97 to 02/99) were retrospectively analyzed. They were between 19 and 59 years old with an average age of 37. Except for Fitzpatrick skin type IV and V, no exclusion criteria were made. Patients with hormonal imbalance were also included, to determine the efficacy of the long-pulsed alexandrite laser over a wide and unselected patient population.

The patients were all treated with a long-pulsed alexandrite laser (PhotoGenica LPIR/Apogee, Cynosure Inc., wavelength 755 nm, pulse duration 5, 10, 20, 40 ms, energy fluence 1-50 J/cm2, repetition rate up to 1 Hz, spot size 7, 10, 12.5 or 16 mm). A beam diameter of 10 or 12.5 mm and a pulse width of 20 msec at a repetition rate of 1 Hz were used for the hair removal. The energy fluence was set according to skin type and hair color. Fitzpatrick skin types I-II with dark hair were treated with increasing fluences from 20 J/cm2 up, and for the same skin type with fair hair, increasing fluences from 23 J/cm2 up were used. From skin type III on, energy fluences between 18 and 20 J/cm2 were selected, regardless of hair color.

Local anesthetics were neither desired nor required in any of the cases. Hair length was not below or above 0.5-1 mm. Ice-cooled sonography gel was applied on the skin directly before treatment to prevent damage to the epidermis. Immediately after treatment, cool packs were placed on the treated areas for approximately 10-15 minutes to diminish any burning sensations. Laser sessions took place at 4-week intervals. Patients were instructed not to manipulate any crusting which may have developed and to avoid the sun for up to 4 weeks following treatment.

To determine hair removal efficacy, each patient was photographed before starting treatment and before each individual laser session. The clearance rates were compared using the photographs by the patients themselves and two independent doctors and rated according to a scale from 0-100%. Each time the entire treated area was evaluated. Every visit, patients were asked about and examined for side effects.

According to the retrospective study design, a treatment-free post-observation period was not planned. Additionally, the extraction of sample biopsies was not done because of the exposed treatment area of the face. A further study with the long pulse alexandrite laser, which includes biopsies from the axilla, back, and chest after treatment, is currently being put together.

The photo documentation was done with a Canon (Type EOS 100) camera and an Agfa (Type Ctx 100) slide film.

Results

Ninety per cent of the patients had Fitzpatrick skin type II, 10% skin type III. Before the laser treatment, 83% of the patients had undergone symptomatic hair removal methods (waxing, plucking, shaving, bleaching, hair removal cream), 17% electrolysis/thermolysis. Thirty-three per cent of the patients showed pathological androgen levels while 17% were normal. A pre-treatment endocrinological examination was not carried out on 50% of the patients. Thirteen per cent of the patients with a pathological androgen level had a hormone treatment consisting of antiandrogens, which had already been started before laser therapy in all cases. Eighty-three per cent of the patients had black or brown hair, 13% mixed black and fair-haired (white/blonde), one patient (4%) had black and reddish-blonde hair.

On average, 8 treatments with an average energy fluence of 25.6 J/cm2 were necessary to achieve a clearance rate of 75%. Fair and red hair showed a clearance rate of only 10%. Hyper- and hypopigmentation as well as scarring did not occur. The most frequent side effect was fine, scar-free scattered crusting in 17% of the patients. Folliculitis occasionally developed in 13%, which healed without consequences as well. The average post-treatment observation time was 3.25 months.

Forty-three per cent of the patients indicated that they were very satisfied with the success of the treatment, 47% were satisfied and only 10% of the patients assessed the result as unsatisfactory.

A summary of the results is shown in Table I.

Discussion

Many individuals, especially women, seek to reduce their facial hair. Although ­ in the age of laser medicine ­ a variety of epilating methods are availiable, patients and physicians ask for improved, effective, safe and long-lasting techniques. At the moment several laser (Q-switched Nd:YAG laser, long-pulsed ruby laser, long-pulsed alexandrite laser, diode laser) and laser-like systems (Photoderm®, Epilight®) with differing wavelengths, pulse durations, and energy densities are examined.

In comparison with the long-pulsed ruby and long-pulsed alexandrite lasers, the Q-switched Nd:YAG makes for the greatest degree of hair regrowth and has at the same time the lowest rate of side effects [6-9]. The long-pulsed ruby and alexandrite laser do not seem to show any significant differences in their results and their side effects [6-9]. The studies with the longest post-treatment observation times are on the ruby laser (wavelength 694 nm) [10-12] and the Epilight® [13-15], an intense pulsed light source (wavelength 500-1.200 nm) and, therefore, not actually a laser by definition. Diode lasers (wavelength 800 nm), which have been on the market for a few months, could also prove very interesting in the future. First reports about these lasers announce long-lasting hair removal with a low rate of side effects [16].

The long-pulsed alexandrite laser (wavelength 755 nm) is available with a pulse duration from 2 msec to 40 msec, depending on the manufacturer. Finkel et al. [17] achieved good results in the treatment of hypertrichosis on the entire body in a study with the long-pulsed 2 msec alexandrite laser (Sharplan EpiTouch 5100, energy fluence 25-40 J/cm2, beam diameter 5-7 mm, repetition rate 5 Hz). Fair and dark hair both responded equally to the treatment. Before the second treatment, the mid-number of hairs fell to 65%, and then, three months after the last treatment, to 12%. The total numer of treatments ranged from 3 (sideburns, bikini line, legs, and breast) to 5 (womens' upper lip). Side effects were minimal and transient.

Our study indicates an average clearance rate of 75% after an average of 8 treatments of facial hypertrichosis (Figs. 1a and 1b) with a larger beam diameter (10-12.5 mm) and longer pulse widths. The rate of side effects was very low. However, we reached an extremely poor clearance rate with fair and red hair, which is contrary to the good results of Finkel et al., although we theoretically had better treatment parameters (pulse duration 20 versus 2 msec, beam diameter 7 versus 10 and 12.5 mm). The poor response of blonde, red and white hair can be explained by their decreased content of eumelanin or by their content of pheomelanin, which differs in its absorption maximum from eumelanin. The patients' satisfaction with the success of the treatment was remarkable. A total of 90% of the patients indicated that they were either very satisfied or satisfied with the result of the treatment. In recent studies, the long-pulsed alexandrite laser achieved success rates that were equal to those of the long-pulsed ruby laser; the rate of side effects was quite similar, too [6-9].

Contrary to theoretical considerations, current studies show that a prolongation of the pulse duration on the long-pulsed alexandrite laser does not lead to the expected results. Nanni et al. compared the efficacies of the long-pulsed alexandrite laser with pulse durations of 5, 10, and 20 msec [5]. They could not find any significant differences in clearance and side effects among the examined groups after 1 week, 1 and 3 months. Boss et al., who used 2 and 20 msec, did not ascertain any differences among the pulse durations after a 6 month post-treatment observation period either [4].

In our study, the long-pulsed alexandrite laser with a pulse duration of 20 msec proved to be a good method of treatment for facial hypertrichosis, with very few side effects. To what extent and whether a pulse duration of 40 msec, which is not offered in series, but as an extra, can increase the efficacy of this laser, still remains unclear and rather questionable due to the results of the study of Nanni et al. and Boss et al. [4, 5].

However, a longer post-treatment observation time is necessary in order to be able to make a reliable statement regarding the permanence of the success of the treatment. In connection with the long-pulsed alexandrite laser, patients and doctors (who are prospective buyers) should be told about "long-term" epilation and not about permanent epilation until more scientific data is available on its effectiveness, in spite of good results and high patient satisfaction.

Article accepted on 6/11/99

REFERENCES

1. Alster TS. Q-switched alexandrite laser treatment (755 nm) of professional and amateur tattoos. J Am Acad Dermatol 1995; 33: 69-73.

2. Anderson RR, Parrish JA. Microvasculature can be selectively damaged using dye lasers: a basic theory and experimental evidence in human skin. Lasers Surg Med 1981; 1: 263-76.

3. Anderson RR, Parrish JA. Selective photothermolysis: precise microsurgery by selective absorption of pulsed radiation. Science 1983; 220: 527-42.

4. Boss WK, Usal H, Thompson RC, Fiorillo MA. A comparison of the long-pulse and short-pulse alexandrite laser hair removal system. Ann Plast Surg 1999; 42: 381-4.

5. Nanni C, Alster TS. Long-pulsed alexandrite laser-assisted hair removal at 5, 10, and 20 millisecond pulse durations. Lasers Surg Med 1999; 24: 332-7.

6. Kilmer SL, Chotzen V, Calkin J. Hair removal study comparing the Q-switched Nd:YAG, long pulse ruby and alexandrite lasers. Lasers Surg Med 1998 (suppl. 10): 203.

7. Nanni C, Alster TS. A practical review of laser-assisted hair removal using the Q-switched Nd:YAG, long-pulsed ruby, and long-pulsed alexandrite lasers. Dermatol Surg 1998; 24: 1399-405.

8. Nanni C, Alster TS. Efficacy of multiple hair removal sessions using the Q-switched Nd:YAG, long-pulsed ruby, and long-pulsed alexandrite laser systems. Lasers Surg Med 1998 (suppl. 10): 40.

9. Nanni C, Alster TS. Laser-assisted hair removal: side effects of Q-switched Nd:YAG, long-pulsed ruby, and long-pulsed alexandrite lasers. J Am Acad Dermatol 1999; 41: 165-71.

10. Dierickx CC, Grossman MC, Farinelli WA, Anderson RR. Long-pulsed ruby laser hair removal. Lasers Surg Med 1997 (suppl. 9): 167.

11. Dierickx CC, Grossman MC, Farinelli WA, Anderson RR. Permanent hair removal by normal-mode ruby laser. Arch Dermatol 1998; 134: 837-42.

12. Grossman MC, Dierickx C, Farinelli BS, Flotte T, Anderson RR. Damage to hair follicles by normal-mode ruby laser pulses. J Am Acad Dermatol 1996; 35: 889-94.

13. Gold MH, Bell MW, Foster TD, Street SS. Long-term epilation using the EpiLight broad band, intense pulsed light hair removal system. Dermatol Surg 1997; 23: 909-13.

14. Schroeter CA, Raulin C, Hürlimann W, Reineke T, De Potter C, Neumann M. Hair loss in 40 hirsute women with an intense light source, the Photoderm VL. Eur J Dermatol 1999; 9: 374-9.

15. Weiss RA, Weiss MA, Marwaha S, Harrington AC. Hair removal with a non-coherent filtered flashlamp intense pulsed light source. Lasers Surg Med 1999; 24: 128-32.

16. Dierickx CC, Grossman MC, Farinelli WA, Anderson RR. Hair removal by a pulsed, infrared laser system. Lasers Surg Med 1998 (suppl. 10): 201.

17. Finkel B, Eliezri YD, Waldman A, Slatkine M. Pulsed alexandrite laser technology for noninvasive hair removal. Journal of Clinical Laser Medicine and Surgery 1997; 15: 225-9.


 