Home > Journals > Biology and research > Annales de Biologie Clinique > summary
 
      Advanced search    Shopping cart    French version 
 
Latest books
Catalogue/Search
Collections
All journals
Medicine
Biology and research
Annales de Biologie Clinique
- Current issue
- Archives
- Subscribe
- Order an issue
- More information
Public health
Agronomy and biotech.
My account
Forgotten password?
Online account   activation
Subscribe
Licences IP
- Instructions for use
- Estimate request form
- Licence agreement
Order an issue
Pay-per-view articles
Newsletters
How can I publish?
Journals
Books
Help for advertisers
Foreign rights
Book sales agents



 

Texte intégral de l'article
 
Printable version


Annales de Biologie Clinique. Volume 63, Number 3, 305-13, Mai - Juin 2005, pratique quotidienne

Résumé   Article gratuit  

Author(s) : F Imbert-Bismut, D Messous, A Raoult, T Poynard, JJ Bertrand, PA Marie, V Louis, C Audy, JM Thouy, B Hainque, A Piton

Summary : The follow up of patients with chronic liver diseases and the data from multicentric clinical studies are affected by the variability of assay results for the same parameter between the different laboratories. Today, the main objective in clinical chemistry throughout the world is to harmonise the assay results between the laboratories after the confirmation of their traceability, in relation to defined reference systems. In this context, the purpose of our study was to verify the homogeneity of haptoglobin, apolipoprotein A1, total bilirubin, GGT activity, ALAT activity results, which are combined in Fibrotest and Actitest, between Dimension ® Analysers RXL, ARX and X-PAND (Dade Behring Society). Moreover, we verified the transferability of Fibrotest and Actitest results between the RXL, and either the BN2 (haptoglobin and apolipoprotein A1) or the Modular DP (total bilirubin, GGT and ALAT activity concentrations). The serum samples from 150 hospitalised patients were analysed on the different analysers. Specific protein assays were calibrated using solutions standardised against reference material on Dimension ® and BN2 analysers. Total bilirubin assays were performed by a diazoreaction on Dimension ® and Modular DP analysers. The GGT and ALAT activity measurements on the Dimension ® analysers were performed in accordance with the reference methods defined by the International Federation of Clinical Chemisty and Laboratory Medicine (IFCC). On the Modular, enzyme activity measurements were performed according to the Szasz method (L-γ- glutamyl-4-nitroanilide as substrate) modified by Persijn and van der Slik (L-γ- glutamyl-3-carboxy- 4-nitroanilide as substrat) for GGT and according to the IFCC specifications for ALAT. The methods of enzymatic activity measurement were calibrated on the Modular only. Liver fibrosis and necroinflammatory activity indices were determined using calculation algorithms, after having adjusted each component’s result of Fibrotest and Actitest for gender and age. Our study has shown, for each parameter, harmonious results between the Dimension ® analysers and between RXL and BN2- Modular DP. Disregarding alpha-2 macroglobulin which cannot be assayed on RXL, the results of Fibrotest and Actitest were similar as performed on BN2- Modular DP and RXL.

Keywords : transferability of results, Fibrotest, Actitest

 

About us - Contact us - Conditions of use - Secure payment
Latest news - Conferences
Copyright © 2007 John Libbey Eurotext - All rights reserved
[ Legal information - Powered by Dolomède ]